IMC Networks IE-MiniMc Manual de Instruções Página 7

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 12
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 6
3
DC Terminal Block Wiring Instructions
The IE-MiniMc LFPT and Telco/LFPT can also be powered with the DC terminal
block. From a power source, connect to any one positive and any one negative
terminal on the IE-MiniMc LFPT and Telco/LFPT. Shown below are the IE-MiniMc
LFPT (left) and IE-MiniMc Telco/LFPT (right).
+5to24VDC
+5to24VDC
+12to48VDC
Non-Telco Power Telco Power
NOTE
When using stranded wire, the leads must be tinned. The DC terminal block is
protected against mis-wiring; if mis-wired, the chassis will not function. The chassis
is internally connected to the negative power terminal.
Cascading DC Power
When installing multiple IE-MiniMc LFPT and Telco/LFPT units on a DIN rail, the end
user can connect to one DC input source, and then cascade from one DC block to
the next, until reaching the maximum current available.
Vista de página 6
1 2 3 4 5 6 7 8 9 10 11 12

Comentários a estes Manuais

Sem comentários