iMcV-E1-Mux/4 Operation Manual

Página 2 - Warranty

6 E1 RJ-48 Connectors ALARM: • OFF during normal operation • Blinks red+green simultaneously when CV errors detected on the E1 line at far end of the

Página 3

7 Connector Pinout and DIP Switch Assignments DIP Switch Assignments A single 10-position DIP Switch is located on the unit to set the configuration.

Página 4

8 10/100BaseT Ethernet Mating Connector Pinout The following table lists the pin configuration for the standard RJ-45 Ethernet connector. Pin Signa

Página 5 - Part Number Description

9 RS-232 Port Mating Connector Pinout The following table lists the pin configuration for the RS-232 port mating connector. Pin Signal 1 None 2 Non

Página 6 - Console RS232

10 Installation Instructions Each iMcV-E1-Mux/4 module requires two adjacent slots in an iMediaChassis or MediaChassis. To install the module in a ch

Página 7

11 Configuration Options The following sections describe the configurable features. Use the "default" command to restore the unit's d

Página 8

12 FX LinkLoss (FXLL) FX LinkLoss is a link integrity monitoring feature that forwards fiber link faults to the RJ-45 DATA port to indicate that a fib

Página 9

13 Loopback Each E1 port can be tested in loopback mode by enabling either a Host loopback or Remote loopback test path. This capability allows the e

Página 10

14 Console Screens Configuration Using the Console Port The following section describes configuration using the console screens. The Remote module is

Página 11

15 Main Menu From the main menu, the end-user can view essential unit configuration data—including active alarms in order of importance—and a clock in

Página 12

ii FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class B computing device, pursu

Página 13 - Pin Signal

16 Menu Options 1 = Refer to the Unit Configuration Screen 2 = Refer to the Port Alarm Status screen 3 = Refer to the SFP Line Status screen; SFP DD

Página 14

17 Port Alarm Status Screen The Port Alarm Status screen displays the status of the Host and Remote alarms on each of the unit's ports. This scr

Página 15

18 Ethernet Port Configuration Screen The screen displays the current values for items 1 through 9 for both the Host and Remote site. Enter the

Página 16

19 E1 Port Configuration Screen Use this screen to access the loopback and name details for each of the four E1 ports. Enter the number of the menu

Página 17

20 Enter the number of the menu item to edit, and enter the new value(s) when prompted.

Página 18

21 Troubleshooting • All iMcV-E1-Mux/4 units are shipped configured as Host units via DIP Switch #1 = OFF. The Remote unit should be set to DIP Switch

Página 19

22 Fiber Optic Port Verification As a troubleshooting aid, the fiber optic ports can be verified by placing a physical loopback optical line on the po

Página 20

23 E1 Port Verification By placing a physical loopback connection on the E1 port, a valid signal can be detected by each individual E1 port to verify

Página 21

24 Normal Operation Under normal operation the following LED display is given: E1E1E1E1E1E1E1E110/100BaseT10/100BaseTRS-232RS-232GREEN STATGREENACT, L

Página 22

25 • Use fiber patch cords (or connectors, if the fiber is terminated) from a reputable supplier. Low-quality components can cause many hard-to-diagn

Página 23

iii Table of Contents FCC Radio Frequency Interference Statement ------------------------------------------------ ii Warranty-------------------------

Página 24

26 2. Wear an ESD wrist-grounding strap before handling any module or component. If a wrist strap is not available, maintain grounded contact with th

Página 25

27 Specifications Power Consumption (Typical): 0.96A @ +5V DC Operating Temperature: 32° to 122° F (0° to 50° C) Storage Temperature: -40° to 160°F (-

Página 26 - WARNING

28 Definition of Terms/Acronyms The following are terms and phrases used within this manual (shown in italics), or which are found in documents associ

Página 27

29 LED Light Emitting Diode: A small stack of lights to indicate link, duplex or other options. LFPT Link Fault Pass-Through: LFPT can be enabled via

Página 28

30 IMC Networks Technical Support Tel: (949) 465-3000 or (800) 624-1070 (in the U.S. and Canada); +32-16-550880 (Europe) Fax: (949) 465-3020 E-M

Página 29

31 Safety Certifications CE: The products described herein comply with the Council Directive on Electromagnetic Compatibility (2004/108/EC). Eu

Página 30

19772 Pauling • Foothill Ranch, CA 92610-2611 USA TEL: (949) 465-3000 • FAX: (949) 465-3020 www.imcnetworks.com © 2009 IMC Networks. All ri

Página 31

iv Troubleshooting ----------------------------------------------------------------------------------- 21 Fiber Optic Port Verification---------------

Página 32

1 About the iMcV-E1-Mux/4 Overview The iMcV-E1-Mux/4 is a media converter that transports four independent E1 lines over an existing single (or dual,

Página 33

2 • Four E1 ports on RJ-48 connectors with surge protection • One full bandwidth Ethernet 10/100BaseT port (specific model) • 1+1 protection switching

Página 34

3 Port Interfaces A fully-configured iMcV-E1-Mux/4 includes the following ports: • Four E1 ports on RJ-48 connectors short haul • One 10/100BaseT twi

Página 35

4 iView² is the IMC Networks management software designed specifically for the IMC Networks “iMcV” family of modules. It features a GUI and gives net

Página 36 - Substances (RoHS) directive

5 LED Operation The iMcV-E1-Mux/4 features diagnostic LEDs as explained below. 10/100BaseT Connector LNK: • OFF when port is not linked/connec