iMcV-DS3/E3/STS Repeater Operation Manual

Página 2 - Warranty

7 Transmit LIU Waveshape (Line Build-Out) This switch selects the optimal transmit waveshape for the line build-out distance on the coax line. The tr

Página 3

8 NOTE When the Remote Management feature is enabled on the Remote module, the remote module must either be installed in an unmanaged chassis or in a

Página 4 - Prerequisites

9 The following illustrations show a typical progression of loopback tests (i.e. starting by checking the coax segment at the local side, then the coa

Página 5 - IMC Networks’ iView

10 Installation Troubleshooting General Troubleshooting • During installation, first test the fiber and BNC connections with all troubleshooting featu

Página 6

11 IMC Networks Technical Support Tel: (949) 465-3000 or (800) 624-1070 (in the U.S. and Canada); +32-16-550880 (Europe) Fax: (949) 465-3020

Página 7

12 Safety Certifications UL/CUL: Listed to Safety of Information Technology Equipment, including Electrical Business Equipment. CE: The produc

Página 8

19772 Pauling • Foothill Ranch, CA 92610-2611 USA TEL: (949) 465-3000 • FAX: (949) 465-3020 www.imcnetworks.com © 2009 IMC Networks. All r

Página 9 - ** WARNING **

ii FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class B computing device, pursu

Página 10

iii Table of Contents FCC Radio Frequency Interference Statement ...ii Warranty...

Página 11

About the iMcV-DS3/E3/STS iMcV-DS3/E3/STS is an SNMP-manageable module which converts thin coax signals to single-mode or multi-mode fiber signals at

Página 12

2 Use the Graphical User Interface (GUI) to enable features by using the iView2 SNMP management software. In a managed chassis, the software settings

Página 13

3 DIP Switches The iMcV-DS3/E3/STS DIP Switches are located on S1 and S2 on the PCB. The S2 DIP Switches are factory configured and must not be moved

Página 14 - WARNING!

4 DIP Switch Settings FUNCTION SWITCH SETTINGS RESULT [(D) = Default] Loopback (iView2 Configurable) S1-1: OFF Loopback Disabled (D) S1-1: ON L

Página 15 - 3178738

5 LEDs The iMcV-DS3/E3/STS module features several diagnostic LEDs per port. The LED functions are as follows: LPBK NO LNK PBEO FA NO LNK RM

Página 16

6 Loopback Type This switch controls which data line is looped back when the Loopback DIP Switch is enabled. The data line loopback selection can be