IMC Networks iMcV-DS3/E3-LineTerm Manual de Instruções

Consulte online ou descarregue Manual de Instruções para Transceptores de rede IMC Networks iMcV-DS3/E3-LineTerm. IMC Networks iMcV-DS3/E3-LineTerm Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 20
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
iMcV-DS3/E3/STS-LineTerm
Operation Manual
Vista de página 0
1 2 3 4 5 6 ... 19 20

Resumo do Conteúdo

Página 1 - Operation Manual

iMcV-DS3/E3/STS-LineTerm Operation Manual

Página 2

7 Transmit LIU Waveshape (Line Build-Out) (DIP Switch S1, Position 5) This switch selects the optimal transmit waveshape for the line build-out dista

Página 3

8 Remote Management (DIP Switch S1, Position 10) This switch enables or disables the Remote Management mode. Enabling Remote Management on the Remot

Página 4

9 • Copies the incoming signal back out to the origin while continuing to transmit this signal downstream. • Blocks downstream data from arriving on

Página 5

10 Pseudorandom Bit Sequence (PRBS) Testing To test using the internal Pseudorandom Bit Sequence source, ensure that the Central Office and the Custo

Página 6

11 Installation Troubleshooting General Troubleshooting • The Coax Port can easily be tested using the internal PRBS signal generator and detector an

Página 7

12 Specifications Standards Compliance (DS3, E3/STS, STS): ANSI T1.102-1993 ANSI T1.107.1995 GR-820-CORE DS3, E3/STS, STS Interface: BNC coax 75 +/-

Página 8

13 IMC Networks Technical Support Tel: (949) 465-3000 or (800) 624-1070 (in the U.S. and Canada); +32-16-550880 (Europe) Fax: (949) 465-3020

Página 9

14 Fiber Optic Cleaning Guidelines Fiber Optic transmitters and receivers are extremely susceptible to contamination by particles of dirt or dust, wh

Página 10

15 Electrostatic Discharge Precautions Electrostatic discharge (ESD) can cause damage to any product, add-in modules or stand alone units, containing

Página 11

16 Safety Certifications UL/CUL: Listed to Safety of Information Technology Equipment, including Electrical Business Equipment. CE: The produ

Página 12

ii FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class B computing device, pursu

Página 13

19772 Pauling • Foothill Ranch, CA 92610-2611 USA TEL: (949) 465-3000 • FAX: (949) 465-3020 www.imcnetworks.com © 2009 IMC Networks. All

Página 14

iii Table of Contents FCC Radio Frequency Interference Statement ...ii Warranty...

Página 15

1 About the iMcV-DS3/E3/STS-LineTerm iMcV-DS3/E3/STS-LineTerm is an SNMP manageable module that converts standard thin coax signals ( DS3, E3/STS, ST

Página 16

2 Managed Modules The iMcV-DS3/E3/STS-LineTerm modules can be remotely managed when installed in an iMediaChassis with an SNMP management module. Fo

Página 17

3 DIP Switches The iMcV-DS3/E3/STS-LineTerm DIP Switches are located at S1 and S2 on the PCB. The S2 DIP Switches are factory configured and must no

Página 18

4 DIP Switch Settings FUNCTION SWITCH SET RESULT [(D) = Default] Loopback (iView2 Configurable) S1-1: OFF Loopback Disabled (D) S1-1: ON Loop

Página 19 - 3178738

5 LED Operation The iMcV-DS3/E3/STS-LineTerm module features several diagnostic LEDs per port. The LED functions are: ER LOS PRBS LPBK ER LOS

Página 20

6 Loopback (DIP Switch S1, Position 1) This switch enables or disables the loopback feature. When this feature is enabled, the data line (Coax or Fi

Comentários a estes Manuais

Sem comentários