Imc-networks iMcV-Giga-FiberLinX-II Manual do Utilizador Página 39

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 60
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 38
35
Enter the extra tag
VLAN ID
(for example, 8) and the Priority (optional). These
values must be identical on both iMcV-Giga-FiberLinX-II modules.
The Data Tag is [8 ]
Data Priority is [0 ]
Are Extra Tags left on the Data Port? [ N ]
4.
On the Host iMcV-Giga-FiberLinX-II module, enter
Y
in the
Are Extra Tags
left on the Data Port?
field to accept only the Extra Tag VLAN ID on the
DATA port. On the Remote iMcV-Giga-FiberLinX-II module, enter
N
to have
the Extra Tag VLAN ID added to incoming and removed from outgoing data on
the DATA port.
5.
Press
S
or
F3
to save the settings.
6.
Type
reboot
. Repeat steps for second module.
Now the iMcV-Giga-FiberLinX-II Host/Remote pair are configured to pass only VLAN
ID 8 data from the Host iMcV-Giga-FiberLinX-II to the Remote iMcV-Giga-FiberLinX-
II. VLAN ID 8 tag is removed before sending the data out of the Remote DATA port.
The Extra Tag VLAN ID 8 is added to all data received on the Remote DATA port
before being sent to the Host iMcV-Giga-FiberLinX-II where the VLAN ID 8 tag
remains on the data leaving the Host DATA port.
HOST DATA: REMOTE DATA:
Untagged Untagged
and Tagged Data and Tagged Data
wrapped in Extra
Tag of VLAN ID=8
Host DIP switch
(8) set to ON
Host DIP switch
(7) set to ON
Management is provided through the chassis only.
Vista de página 38
1 2 ... 34 35 36 37 38 39 40 41 42 43 44 ... 59 60

Comentários a estes Manuais

Sem comentários